How to Install
Procedure 15-3 How to Add an Additional Module Cage to MTS 4 (Continued)
9
10
11
12
13
14
15-12
Place the Power Supply Unit on the slide rails in the Module Cage and push it to the back.
Secure the Power Supply Unit to the Module Cage with the two M4x10 Torx screws and lock
the washers.
Connect the power supply cables and optional backup battery cables according to the scheme
below:
Part no
3066551B01 DC Power
3066553B01 AC Power
3066556B02 Batt Sens
3066545B01 DC Power
If Base Radio being added is the second Base Radio in a Module Cage (BR2 or
BR4), DC Power Cable (3066545B01) is already existing in configuration.
Connect the RJ45 cable according to the scheme below:
Part no
3066544B06 RJ45 Cable
Switch ON the Power Supply Unit.
Check the LED indicators to verify the PSU is operating correctly.
Cable type
From
Junction panel / DC2 PSU2 / DC In
Cable
Junction panel / AC
Cable
In 2
Junction panel / Bat
cable
Temp 2
BR3 / DC In
Cable
BR4 / DC In
Site Controller /
Power
Cable type
From
PSU2 /
CAN1
Chapter 15: Expansion Options
To
PSU2 / AC In
PSU2 / Battery Temp.
Sens.
PSU2 / DC Out
To
CAN socket where terminator
is situated (terminator to be
removed and replaced by the
cable instead). Could be on a
filter or ATCC. In case of no
redundant Site Controller, the
terminator should be placed in
PSU 2/ CAN 2 output.
6802800U74-N September 2009