Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_RX_NVM_CKSUM_FAULT
ALM_RX_NVM_CKSUM_FAIL
ALM_RX_FRU_BAND_MIS-
MATCH
ALM_AMBI-
ENT_TEMP_ALM_WARN
ALM_AMBIENT_TEMP_WARN
ALM_AMBI-
ENT_TEMP_ALM_FAULT
ALM_AMBIENT_TEMP_FAULT
6802800U74-N September 2009
Recovery
Description
Action
Checksum
Software
fault for the
attempts to set
Receiver NVM
the parameters
parameters was
to the default
detected during
values taken
initialization
from the default
- some of
region in the
the Receiver
NVM memory.
configuration
parameters may
be corrupted.
The same as ALM_RX_NVM_CKSUM_FAULT
Band mismatch
No recovery
between BRC
action taken by
the software.
receivers was
detected during
initialization.
Since BRC
has only one
receiver this
alarm should be
never observed.
No recovery
The ambient
temperature
action taken by
is above
the software.
the ambient
temperature
threshold for
the low output
power.
The same as ALM_AMBIENT_TEMP_ALM_WARN
The ambient
BRC is de-keyed
temperature is
by the software
greater than the
if the ambient
allowable high
temperature is
temperature
greater than
threshold or
the allowable
lower than the
high temperature
allowable low
threshold.
temperature
threshold.
The same as ALM_AMBIENT_TEMP_ALM_FAULT
Base Radio Alarms
Clear Action
If the operation
Corrupted
of restoring
configuration
defaults is
parameters may cause
successful the
that BRC works
alarm is cleared.
incorrectly. The
Otherwise the
default values may
alarm status is
be different than the
unchanged.
lost parameter values.
To make sure the
parameters can be
restored manually to
the earlier backed up
values.
The alarm will be
If the alarm is
cleared only after
reported it means
resetting BRC.
some software error.
If the alarm
condition
disappears then
the alarm is
cleared.
If the alarm
condition
disappears the
alarm is cleared
and BRC can be
re-keyed again.
Notes