MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Process 8-6 Adding Redundant Site CONTROLLER (Continued)
6
7
8
Procedure 8-25 Add Additional Site CONTROLLER
1
2
3
4
5
6
7
6802800U74-N September 2009
Load Ki's into MTS. See
Check the MTS post-restoration checks. See
Checks," on page
8-39.
When adding a second Site Controller it will automatically become standby, meaning
that performance of the Site Controller post-restoration checks will not be possible.
In order to perform a Site Controller Post-restoration check on the second Site
Controller, the first Site Controller needs to be reset allowing the second Site
Controller to become active leading to interruption of service for several seconds.
Configure Redundant Site Controller feature. See
Wear an ESD strap and connect its cable to a verified good ground. This strap must be worn
to prevent ESD damage to any components.
Remove the Site Controller Blind Plate.
Label the cables with labels included in the expansion kit.
Connect the Ethernet cables to the Base Radio(s) according to the scheme below:
Part number
3066544B02
3066544B15
3066544B16
3066544B01
At this stage only connect the cables to the Base Radios
Strap the cables.
Connect RF cable 3066543B10 to the GPS2 connector on the Junction Panel and let it hang.
Catch the cable in the empty space where the Site Controller is to be assembled and temporarily
fix it at the front.
Install the Site Controller. Use the handle to slide the unit into the chassis.
Connect the ribbon cables at the rear before sliding the unit into the chassis. Be
careful not to damage the cables when sliding the Site Controller into place.
Secure the Site Controller in the chassis with two M4X10 captive screws.
Process 8-4, "MTS - Loading Ki's Into MTS," on page
Table 8-10, "MTS - Site Controller Post-Restoration
Process 8-7
Cable type
Ethernet cable
Ethernet cable
Ethernet cable
Ethernet cable
How to Install
8-34.
below.
From
SC2 / BR4
BR4 / SC2
SC2 / BR1
BR1 / SC2
SC2 / BR2
BR2 / SC2
SC2 / BR3
BR3 / SC2
To
8-45