Environment and Product Type
5.2
Environment Settings (Environment settings common for all types)
13. Flash
Set to Yes in the case that you wish to use flash illumination. Set this when
you have selected Normal Frame for the camera mode. This initial setting is
Unused.
Flash
Unused
Yes
Yes(ANM830A)
Note
If the standard camera being used is the ANM830A, set this to
Yes (ANM830A).
5.2.3
Start
Set the inspection start method.
Repeated inspection is only possible with the Main menu (Checker and Spreadsheets),
Numerical Calculation menu, Judgment menu and Spreadsheets menu.
− Once
When A is pressed, or if a start input is received from the parallel interface or
a start command is received from the serial interface, a single inspection is
performed.
− Manual Repeat
When A is pressed, or if a start input is received from the parallel interface or
a start command is received from the serial interface, continuous repeated
inspection commences until A is pressed again. (Inspection stops even if
another start input is received from the parallel or serial interface.)
− Auto Repeat
Continuous repeated inspection commences as soon as the power is turned on.
Inspection stops when A is pressed. After inspection stops, restarting is the
same as for Repeat (manual).
A button
Once
Single inspection
Manual Repeat/
Continuous
Auto Repeat
inspection
5 − 6
Parallel start
Serial (%S)
Single inspection
Single inspection
Continuous
Continuous
inspection
inspection
OCR Type A230
Serial (%P)
Serial (%R)
Single inspection
Single inspection
Continuous
Single inspection
inspection

Advertisement