Download Print this page

Panasonic A230 User Manual page 102

Machine vision system

Advertisement

Position and Rotation Adjustment
6.2
The Various Modes for Position/Rotation Adjustment Checkers
Setting the base position
A position and rotation adjuster is a checker that obtains the amount of adjustment
between the coordinates (reference point) set at the time the checker is set up, with the
coordinates at the time the checker is executed. A test must be conducted to set the
reference point. (If the setting is for a camera image, a new image is captured when the
test is conducted.) The following confirmation message is displayed if you attempt to
terminate the setting procedure without conducting a test and setting a base position.
If you select Yes, the settings and changed data will be lost. Unless you want to
abandon the setup procedure and lose the settings, select No and set the reference
position.
The base position is automatically cleared whenever changes are made to shape, area,
or priority setting. When any of these items have been changed, set the base position
and the position and rotation adjuster again.
If only a horizontal base checker has been set, the display shows only the value for the
X coordinate, and if only a vertical base checker has been set, the display shows only
the value for the Y coordinate. (For position and rotation adjustment, the angle is fixed
and displayed as 0, and for rotation adjustment, the reference angle is displayed.) The
amount of adjustment for a direction which has not been set is fixed and displayed as
0.
When the base position has been reset, checkers dependent on the adjustment are
displayed at the newly adjusted positions.
If an angle of rotation is applied, the following message is displayed.
If you select Yes, dependent checkers are reset at the previous execution position, but
at this point they are reset with the angle of inclination disappearing.
Select No if you do not want to change the execution positions of dependent checkers.
Resetting at the base position is canceled.
Notes
Conditions for changing execution position:
When position and rotation adjuster has been deleted:
All dependent checkers return to their original setting
positions. Next execution is from the setting position.
When a dependent checker with rotation angle adjusted is
reset:
The dependent checker is reset with angle 0 close to the
previous execution position.
6 − 10
OCR Type A230

Advertisement

loading