Error Output
18.2
Error Signal Output Conditions (Parallel)
Numerical calculation register
− When a referenced checker does not exist.
− When a formula is not registered in the referenced numerical calculation register.
− When a 32−bit overflow occurs during calculation.
− When a zero divide occurs during calculation.
Judgment output register
− When a referenced checker does not exist.
− When a formula is not registered in the referenced numerical calculation register or
judgment output register.
− When a numerical calculation register or judgment output register that has generated
an error is referenced.
Camera switching error conditions
− If you attempt to switch cameras using one of the following methods with a setting for
Type Menu − Capture Camera is something other than AB.
− The "Easy" switch (camera A to/from camera B) signal was input.
− With the capture camera set at either A, AB Vertical Division, or AB Horizontal
Division, a switch signal specifying camera B (either Thru or Mem) was input.
− With the capture camera set at B, a switch signal specifying camera A (either
Thru or Mem) was input.
− Camera switching failed.