16.2.4
Serial Output Settings (Normal Mode)
Select the data, signals and format for performing serial communication using Normal
Mode.
431. Output
Set the number of digits in the output data (setting range: 1 to 11).
432. Output Char.
Set the maximum number of characters that can be recognized per a
checker.
433. Inval. Digit
Set the method of handling invalid digits in the output data.
If you select Del, the data is handled as variable−length data, and if you
select Replace the data is handled as fixed−length data with the number
of digits specified in the Output setting.
434. Read End
Select whether or not to perform serial output of the Image Capture
Complete signal (%R).
435. Process End
Select whether or not to perform serial output of the Inspection
Complete signal (%E).
436. Numerical Calc.
Select whether or not to perform serial output of results of numerical
calculations.
437. Judgment
Select whether or not to perform serial output of the judgment results.
438. Char. Recog.
Set whether or not to output the recognized string.
Communications (Serial and Parallel)