Download Print this page

Panasonic A230 User Manual page 197

Machine vision system

Advertisement

OCR Type A230
10.1 About Lead Inspection Checkers
2. Checker
24.LeadInspection
You can use the Lead Inspection function to count IC and connector pins and measure
their pitch and width. You can also set judgment conditions for these parameters.
You can set up to a maximum of 32 Lead Inspection checkers for each product type.
Number of leads
Pitch
The procedure for using Lead Inspection checkers is as follows.
1.
Select LEAD INSPECTION from the menu.
2.
Specify a number for the Lead Inspection checker.
3.
If there are two cameras connected, select either camera A
or camera B for performing the inspection.
4.
Specify inspection process conditions such as inspection
range and scan direction.
5.
Set judgment conditions as required.
6.
Select Position/Rotation Adjustment checkers if you intend to
perform position or rotation adjustment.
7.
Press the A (Test) key to initiate lead inspection, and verify
the results.
Select Camera
Shape
Checker Setting
Direction
Area
Object
Edge Thres. Value
Condition
Detect Judgment
Width Judgment
Pitch Judgment
Pos. Rot. Adj. Group
Result
Copy Checker
Delete Checker
Width
Lead Inspection Checker
10.1 About Lead Inspection Checkers
10 − 3

Advertisement