Download Print this page

Panasonic A230 User Manual page 116

Machine vision system

Advertisement

Position and Rotation Adjustment
6.3
Setting a Position/Rotation Adjustment Checker
3.
Select Theta Rot. Adj.
The setting menu for theta rotation adjustment using
matching is displayed. Use Select Camera to select the
camera, and Delete Checker to delete the checker as
required.
[1] POS. ROT. ADJ.
No. 1
Matching:Theta Rot.
1.
2.
3.
4.
5.
1.
Select Camera
Select either the camera A or camera B image for operating the Position
Adjustment checker.
2.
Checker Setting
Use this to create the checker and set items such as the scan conditions.
3.
Base Pos.
Execute a test to register the base point for adjustment.
4.
Pos.Rot. Adj. Group
Set which checker is to be used for adjustment in the case that you are using
multiple settings for position and rotation adjustment. Select a group number.
Refer to Position Adjustment Groups (page 6 − 31) for details.
5.
Delete Checker
Use this to delete a checker.
Note
If you delete a Position Adjustment checker, the inspection
results for all checkers that follow the deleted checker are
cleared.
6 − 24
Jud:NG
Select Camera
Checker Setting
Base Pos.
(−−−−−, −−−−−, −−−−−)
Pos. Rot. Adj. Group
Delete Checker
B
Empty
0
OCR Type A230

Advertisement

loading