Machine vision system

Advertisement

Communications (Serial and Parallel)
16.8
Template (Smart matching) Re−registration
− Timing Chart
Setting, Execution, Position Adjustment, and Re−registration Area Display = NO
Template No.
/IN1 to /IN2
/READY
Ready signal
Template
/IN8
re−registration
input
(A): When READY is on, input the template number, IN1 to IN2.
(B): When READY is on, input IN8.
(C): READY goes off. After the template image is updated, READY goes back on.
Setting, and Re−registration Area Display = YES
Template No.
/IN1 to /IN2
Ready signal
ON
/READY
Template
/IN8
OFF
re−registration
input
The re−registration area is dis-
played. If the display is binarized,
it is temporarily changed to gray
scale.
(A): When READY is on, input the template number, IN1 to IN2.
(B): When READY is on, input IN8.
(C): READY goes off, and the template image re−registration area is displayed.
If an error occurs at this point (*1), processing is cancelled and an ERROR signal
is output.
(D): While READY is off, input IN8 again.
(E): After the template image re−registration area disappears, the template image is
updated, and READY goes back on.
(*1) Typical causes of an error occurring at this point:
− You specified a non−existent checker.
− The specified checker number is set for an image from a camera other than that
set for the capture camera.
16 − 44
(A)
OFF
(C)
ON
(B)
OFF
ON
Setting: Re−registration executed.
Execution: Re−registration executed after execution of smart
matching.
Adjustment: Re−registration executed after execution of
position adjustment. If a Thru image is displayed, operation
is as above after the image capture is executed.
(A)
OFF
(C)
(B)
ON
(E)
(D)
ON
Re−registration is performed at the
setting position. In the case of Thru
display, the image is captured before
the re−registration is performed.