5.3.3.1

sntp time diff

Description
With this command, you configure the time difference of the system time relative to the UTC
time.
Requirement
● The SNTP server must have started up.
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+
-
hh
mm
Enter the time difference as follows:
● with sign
● without spaces
● Hours and minutes both two digits (with leading zero)
Default: no time difference
Result
The time zone of the system time is configured.
Further notes
You can display the settings of this function and other information with the
status
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Time zones to the west of the SNTP server time zone
Time zones to the east of the SNTP server time zone
Number of hours difference
Number of minutes difference
command.
System time
5.3 SNTP client
show sntp