• Instantaneous power failure may cause system mal-function or battery failure. Therefore
use a stable supply of AC power.
• Using the power cable that comes with the OfficeServ 7150 system, connect the power
input port at the rear of the cabinet to a grounded electric outlet.
CONNECTING THE 7150 TO THE OFICESERV 7200
1) Make sure All AC power and battery connections to the OfficeServ 7150 and OfficeServ
7200 are disconnected before proceeding.
2) Connect the plastic connector end of the PoE cable into the back of the OfficeServ
7200 connector labeled "PoE Input".
3) The other ends of the PoE cable will have a Red wire and a Blue wire. Connect the Red
wire to the first GND lug from the left on the back of the 7150. Connect the Blue wire
to the first -54V lug from the left on the back of the 7150.
4) If connection to a second OfficeServ 7200 cabinet is required, then repeat the steps
above and connect the red wire to the 2
the second +54V lug from the left.
5) Power on the 7200 cabinets.
6) Power the OS 7150 ON by turning on the power switches on each PoE-M PSU modules
and if a battery is connected, turn on the BATT switch to the ON position on the front
of the 7150.
Figure 5.13 Power Connection
GND lug from the left and the blue wire to
nd
5.14
Home Page
INSTALLATION
PART 5 MAY 2010
(See Figure 5.14)