TECHNICAL MANUAL
MMC: 729
DESCRIPTION:
The RATE CALCULATION TABLE is used to define the billing charges for each
COST RATE. These rate tables correlate with the Trunk Cost Rate and the Costing
Dial Plan. There are eight call costing rates. Each rate has the following data fields.
FIRST INTERVAL DURATION: This is the amount of time at the beginning of each
call to which a fixed cost is applied. The range is from 0 to 999 seconds, for
example, 180 seconds (three minutes).
FIRST INTERVAL COST: This is the dollar cost for the first interval duration. The
range is from 0 to 999, for example, 345 ($3.45).
SECOND INTERVAL DURATION: This is the amount of time for the duration of each
billing increment after the first interval has expired. The range is from 0 to 999
seconds, for example, 006 seconds (six seconds).
SECOND INTERVAL COST: This is the dollar cost for each billing increment. The
range is from 0 to 999, for example 100 ($1.00).
SURCHARGE: This is a one-time charge that is applied to the call over and above
the time charges. The range is from 0 to 999, for example 150 ($1.50).
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPEAKER
HOLD
ANS/RLS
ACTION
1. Press TRANSFER 729.
Display shows COST RATE and FIRST
INTERVAL DURATION.
RATE CALCULATION TABLE
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
Used to clear previous entry
Used to select all
DISPLAY
COST RATE [1]
1ST DUR:000