Troubleshooting
Appliance Does Not Recognize New Memory Configuration
Problem DIMMs are not properly seated in DIMM sockets.
Solution Repeat memory installation procedures. Make sure DIMMs are
fully seated in sockets. Be sure DIMMs click into place.
Appliance locks up after you upgrade IPSO with a console
connection. No error messages appear, but the appliance
stops responding to console and network.
Problem During the upgrade process, some of the environment variables
might not have updated correctly.
Solution You can verify what the current boot manager settings are by
issuing a
example:
Loading boot manager ..
BOOTMGR[0]> printenv
Bootmgr Revision: 3.3,base kernel=3.5.1-fcs1
02.12-2001-102644
autoboot: NO
bootwait: 5
boot-file:
boot-flags:
boot-device:
No referenced boot-file or boot-device appears.
Setting the boot manager to defaults causes the boot manager to determine
that no environment variables are set, and it responds by importing the
defaults from the binary file. To set the boot manager to defaults, issue the
set-defaults
example:
BOOTMGR> set-defaults
94
command at the boot manager prompt, as shown in this
printenv
command at the boot manager prompt as shown in this