The interconnect tests are disabled by default and must be enabled to run separately.
Step 5.
Run the interconnect diagnostics test from the Maintenance mode prompt:
interconnect
You only need to run the interconnect test from one controller.
Step 6.
Verify that no hardware problems resulted from the replacement of the chassis:
-dev interconnect -long -state failed
System-level diagnostics returns you to the prompt if there are no test failures, or lists the full status
of failures resulting from testing the component.
Step 7.
Proceed based on the result of the preceding step.
sldiag device run -dev
sldiag device status
.
Chapter 5
Hardware replacement procedures
93