Chapter 6. System Level Diagnostics; Introduction To System-Level Diagnostics; Requirements For Running System-Level Diagnostics - Lenovo ThinkSystem DM3000x Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

Chapter 6. System level diagnostics

Introduction to system-level diagnostics

System-level diagnostics provides a command-line interface for tests that search for and determine
hardware problems on supported storage systems. You use system-level diagnostics to confirm that a
specific component is operating properly or to help identify faulty components.
System-level diagnostics is available for supported storage systems only. Entering system-level diagnostics
at the command-line interface of unsupported storage systems generates an error message.
You run system-level diagnostics after one of the following common troubleshooting situations:
• Initial system installation
• Addition or replacement of hardware components
• System panic caused by an unidentified hardware failure
• Access to a specific device becomes intermittent or the device becomes unavailable
• System response time becomes sluggish
To run system-level diagnostics, you must already be running Data ONTAP because you need to reach the
Maintenance mode boot option in Data ONTAP. There are several approaches to get to this option, but this
is the recommended approach taken in the procedures documented in this guide. Some hardware
components in your system may require a specific approach, and this would be documented in the
applicable field replaceable unit (FRU) flyer. This guide does not provide detailed definitions of specific
commands, subcommands, tests, or conditions.
Once the command is entered, the tests run in the background and the passed or failed outcome of the tests
is logged in the internal memory-based log, which has a fixed size. Some tests are utilities and will simply
state completed rather than passed or failed. After you run the appropriate tests, the procedures
documented in this guide help you generate status report. Once the test results show a successful
completion of system-level diagnostics, it is a recommended best practice to clear the log.
In the event of test failures, the status reports will help technical support make appropriate
recommendations. The failure could be resolved by reinstalling the FRU, by ensuring cables are connected,
or by enabling specific tests recommended by technical support and then re-running those tests. If the
failure cannot be resolved, then there is a hardware failure and the affected hardware must be replaced.
There are no error messages that require further definitions or explanations.

Requirements for running system-level diagnostics

Depending on the system-level diagnostic tests you are running, you need to be aware of time and system
hardware requirements.
Each documented task has slight differences; use the recommended procedure for the task.
The following requirements must be met when running system-level diagnostics; otherwise, parts of the tests
fail and error messages appear in the status report:
General requirements
• Each system being tested must be on a separate network.
© Copyright Lenovo 2019, 2023
97