Chassis - Lenovo ThinkSystem DM3000x Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

Step 1.
If you are not already grounded, properly ground yourself.
Step 2.
Align the end of the controller module with the opening in the chassis, and then gently push the
controller module halfway into the system.
Note: Do not completely insert the controller module in the chassis until instructed to do so.
Step 3.
Recable the console to the controller module, and then reconnect the management port.
Step 4.
Repeat the preceding steps if there is a second controller to install in the new chassis.
Step 5.
Complete the installation of the controller module:
If your system is in...
An HA pair
Step 6.
Connect the power supplies to different power sources, and then turn them on.
Step 7.
Boot each controller to Maintenance mode:
a.
As each controller starts the booting, press
the message Press Ctrl-C for Boot Menu.
Note: If you miss the prompt and the controller modules boot to ONTAP, enter
at the LOADER prompt enter
step.
b.
From the boot menu, select the option for Maintenance mode.
Verifying and setting the HA state of the chassis
You must verify the HA state of the chassis, and, if necessary, update the state to match your system
configuration.
Step 1.
In Maintenance mode, from either controller module, display the HA state of the local controller
module and chassis:
The HA state should be the same for all components.
Step 2.
Proceed based on the results of Step 1.
, press
boot_ontap
ha-config show
Then perform these steps...
1. With the cam handle in the open position,
firmly push the controller module in until it
meets the midplane and is fully seated,
and then close the cam handle to the
locked position.
Attention: Do not use excessive force
when sliding the controller module into the
chassis to avoid damaging the
connectors.
2. If you have not already done so, reinstall
the cable management device.
3. Bind the cables to the cable management
device with the hook and loop strap.
4. Repeat the preceding steps for the second
controller module in the new chassis.
to interrupt the boot process when you see
Ctrl-C
when prompted, and then repeat this
Ctrl-C
.
Chapter 5
Hardware replacement procedures
, and then
halt
91