Running Slow System Response Diagnostics - Lenovo ThinkSystem DM3000x Hardware Installation And Maintenance Manual

Table of Contents

Advertisement

Error Count: 2 Run Time: 70 secs
>>>>> ERROR, please ensure the port has a shelf or plug.
END DATE: Sat Jan 3 23:12:07 GMT 2009
LOOP: 1/1
TEST END --------------------------------------------
If the system-level diagnostics tests...
Were completed without any failures
Resulted in some test failures
After you finish
If the failures persist after repeating the steps, you need to replace the hardware.

Running slow system response diagnostics

Running diagnostics can help you identify the causes of slow system response times.
ThinkSystem DM3000x and DM5000x Hardware Installation and Maintenance Guide
104
Then...
There are no hardware problems and your
storage system returns to the prompt.
1. Clear the status logs by entering the
following command:
clearstatus
2. Verify that the log is cleared by entering
the following command:
status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode by entering the
following command:
4. Enter the following command at the
Loader prompt to boot the storage
system:
boot_ontap
You have completed system-level diagnostics.
Determine the cause of the problem.
1. Exit Maintenance mode by entering the
following command:
2. Perform a clean shutdown and disconnect
the power supplies.
3. Verify that you have observed all the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4. Reconnect the power supplies and power
on the storage system.
5. Repeat Steps 1 through 5 of Running
system panic diagnostics.
sldiag device
sldiag device
halt
halt