• If the cluster is not in quorum or a controller that is not the degraded controller shows
and health, correct the issue before proceeding to the next step.
• If Epsilon resides in the degraded controller:
1. Remove Epsilon from the degraded controller:
2. Assign Epsilon to a healthy controller in the cluster:
About this task
You might want to erase the contents of your caching module before replacing it.
Step 1.
Although data on the caching module is encrypted, you might want to erase any data from the
impaired caching module and verify that the caching module has no data:
a.
Erase the data on the module:
b.
Verify that the data has been erased from the module:
-node node_name
The output should display the caching module status as erased.
Step 2.
If the degraded controller is part of an HA pair, disable automatic giveback from the console of the
healthy controller using the following command:
false
Step 3.
Take the degraded controller to the Autoboot Loader prompt by typing
<impaired node name>
If the degraded controller is displaying...
The LOADER prompt
Waiting for giveback...
System prompt or password prompt

Opening the system

To access components inside the controller, you must first remove the controller module from the system
and then remove the cover on the controller module.
About this task
A video for this task is available at:
• YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-Atzbq4KHJgYQHkA9FCH0-m
Step 1.
If you are not already grounded, properly ground yourself.
Step 2.
Loosen the hook and loop strap binding the cables to the cable management device, and then
unplug the system cables and SFPs (if needed) from the controller module, keeping track of where
ThinkSystem DM3000x and DM5000x Hardware Installation and Maintenance Guide
30
system node flash-cache secure-erase run
from the RJ45 management port of the degraded controller.
cluster modify -node degraded_node -epsilon false
cluster modify -node healthy_node -epsilon true
system node flash-cache secure- erase show
storage failover modify -node local -auto-giveback
Then...
Go to the next step.
Press Ctrl-C, and then respond
prompted.
Take over or halt the degraded controller:
• Take over the degraded controller from the
healthy controller:
-ofnode impaired_node_name
degraded controller shows Waiting for
giveback..., press Ctrl-C, and then respond
.
y
for eligibility
false
storage failover takeover
when
y
storage failover takeover
When the