Fault Messages - ABB ACS560 Quick Installation And Start-Up Manual

Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Fault messages

Code
Fault / Aux.
(hex)
code aux code
visible only on
assistant con-
trol panel and
drive com-
poser))
1080
Backup/Restore
timeout
1081
Rating ID fault
2281
Calibration
Cause
During backup/restore,
communication is lost
between panel/PC tool
and drive.
Drive software is not able
to read the drive rating ID.
Measured offset of output
phase current measure-
ment or difference
between output phase U2
and W2 current measure-
ment is too great (the val-
ues are updated during
current calibration).
Diagnostics 153
What to do
Request backup or restore again.
Reset the fault or cycle the power
to the drive.
If the fault persists, contact your
local ABB representative.
Try performing the current calibra-
tion again.
If the fault persists, contact your
local ABB representative.
EN
HI

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs560-01

Table of Contents