5.4.3 Engineering Labels for Network Cables

Applicable Ranges
The labels can be applied to Ethernet cables.
Label Content
Table 5-24
You can also decide the label content according to the actual environment. If the device is not
installed in the cabinet, for example, you can remove the cabinet number.
Table 5-24 Information on the Ethernet cables
Content
MN-B-C-D
MN-Z
The contents of the labels for network cables connecting hubs and devices or agents and the
network cables for other purposes should be specified according to actual connections. The
details are as follows:
Issue 02 (2015-05-18)
"A01-01-05-01-R" indicates that the opposite end of the optical fiber is connected to
Optical Receiving Interface 1 on Slot 05, chassis 01 in the cabinet on Row A, Column 01
in the machine room.
shows the information on both sides of the labels affixed to Ethernet cables.
Meaning
MN: cabinet
number
B: chassis
number
C: physical slot
number
D: network port
number
MN: cabinet
number
Z: Location
number
For a network cable connecting a hub and device, the label on the hub end should
indicate the numbers of the chassis and cabinet where the hub resides, and the serial
number on the hub. The label on the device end should indicate the number of the
chassis and cabinet where the device is located. If the device is a stand-alone device, the
specific position of the device should be provided.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Example
For example, A01 is the first cabinet in row A.
Numbered in the bottom-up order with two digits,
for example, 01.
Numbered with two digits in top-down and
left-right order. For example, 01.
Numbered in the top-down and left-right orders.
For example, 01.
For example, B02 is the second cabinet in Row B.
Fill in the location number of the terminal device
on site. If the cable is connected to a device in a
cabinet, the serial numbers of the cabinet, the
chassis, and the Ethernet interface of the device
should be specified. For example, B02-03-12. If the
cable is connected to the Network Management
Station (NMS), the specific location of the NMS
should be given.