Huawei AP4030DN Hardware Installation And Maintenance Manual page 35

Hide thumbs Also See for AP4030DN:
Table of Contents

Advertisement

Huawei AP4030DN
Hardware Installation and Maintenance Guide
When you strip a power cable, do not damage the conductor of the cable.
Figure 5-12 Stripping a power cable (cord end terminal)
Table 5-3 Mapping between the cross-sectional area of the conductor and the value of L1
Cross-Section
al Area of
Conductor
(mm
1 (0.002)
1.5 (0.002)
2.5 (0.004)
4 (0.006)
6 (0.009)
Step 2 Putting the cord end terminal onto the conductor, and ensure that the conductor is aligned
with the edge of the cord end terminal, as shown in
After the conductor is fed into the cord end terminal, the protruding part of the conductor
must not be longer than 1 mm (0.04 in.).
Issue 02 (2015-05-18)
Value of L1
(mm(in.))
(in.
))
2
2
8 (0.31)
10 (0.39)
10 (0.39)
12 (0.47)
14 (0.55)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Cross-Sectional
Area of Conductor
(mm
(in.
))
2
2
10 (0.015)
16 (0.025)
25 (0.039)
35 (0.054)
50 (0.077)
Figure
5-13.
5 Appendix
Value of L1
(mm(in.))
15 (0.59)
15 (0.59)
18 (0.71)
19 (0.75)
26 (1.02)