Mitsubishi Electric MELSERVO-J2S Series Manual page 89

Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

(9) When the Built-in Regeneration Resistance Is Used
1. Make sure that terminals P and D on the currently used control power connector to be connected
to the terminal bock (TE2) of Renewal Kit are short-circuited.
2. Connect the cables on terminals P and D of the terminal block (TE2) of Renewal Kit to the
replacing servo amplifier.
* For the details of how to connect the cables, see the technical materials on the MR-J4 servo
amplifier issued by Mitsubishi Electric Corporation.
Make sure that terminals P
and D on the currently used
control power connector
are short-circuited.
(10) When the Regeneration Option Is Used
1. Remove the jumper between terminals P and D on the CNP2 connector of the replacing servo
amplifier.
2. Connect the cables on terminals P and C on the terminal block (TE2) of Renewal Kit to the
replacing servo amplifier.
3. Connect the regeneration option to terminals P and C on the currently used control power
connector to be connected to the terminal block (TE2) of Renewal Kit.
* For the details of how to connect the cables of the regeneration option, see the technical
materials on the MR-J4 servo amplifier issued by Mitsubishi Electric Corporation.
Connect the cables on terminals P
and C of the terminal block of
Renewal Kit.
Remove the jumper from
terminals P and D.
Connector CNP2
Servo amplifier MR-J4-_A
Connector CNP2
Terminal block TE2
Servo amplifier MR-J4-_A
Make sure that the
regeneration option is
connected between
terminals P and C of the
currently used control
power connector.
3-12
3 - 12
Connect the cables on
terminals P and D on the
terminal block of Renewal
Kit to the servo amplifier.
Terminal block TE2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2s

Table of Contents