Mitsubishi Electric MELSERVO-J2S Series Manual page 86

Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

・Type of the servo amplifier・・・The case of Type A with the amplifier capacity of 11kW or higher
You are going to connect the currently used cable to the conversion cable.
CAUTION
The connectors (CN1A, CN1B, and CN2) on servo amplifier MR-J2S-_A are all in the same shape. If
you connect a currently used cable to a wrong connector and turn on power, the amplifier, the
motor, and/or the like may be broken due to the difference in voltage.
Side of the Conversion Cable
変換ケーブル側
制御信号変換ケーブル
Control signal conversion cable
(SC-J2SJ4CTC03M)
エンコーダ変換ケーブル
Encoder conversion cable
(SC-J2SJ4ENC03M)
モニタ変換ケーブル
Monitor conversion cable
(SC-J2SJ4MO2C03M)
CAUTION
The connectors (CN1A, CN1B, and CN2) on the conversion cable are all in
the same shape. Use caution not to make an incorrect connection. If you
make an incorrect connection, the servo amplifier may be broken.
Connectors CN1A, CN1B and CN2 are
all in the same shape. Use caution
not to make an incorrect connection.
Do not fasten the encoder conversion cable and the control signal
conversion cable on a power cable or on a drive cable. Dosing so may cause
an incorrect operation.
Use cable ties (accessories in the package) to fasten and fix the cables
on the control signal conversion cable of Renewal Kit or on the currently
used control signal connection cable.
Side of the Currently Used Cable
CN1A用
For CN1A
CN1B用
For CN1B
3-9
3 - 9
既設ケーブル側
Currently used control
既設制御信号ケーブル
signal cable
Currently used encoder
既設エンコーダケーブル
cable
Currently used monitor
既設モニタケーブル
cable