(3) MR-J2M-P8A series servo amplifier
The initializing time is 3 s.
Main circuit control
circuit power supply
Base circuit
Servo-on (SON)
Reset (RES)
Ready (RD)
(4) MR-J2S-_B_ series servo amplifier
The initializing time is 3 to 4 s.
Servo-on command accepted
Main circuit control
ON
circuit power supply
OFF
ON
Base circuit
OFF
ON
Servo-on command
(from controller)
OFF
SON acceptance
(Note)
(3 s 4 s)
~
95 ms
2-46
10 ms
2 - 46
95 ms