(10) Connecting Currently Used Cables L11 and L21
1. There are currently used cables L11 and L21 connected to the terminal block on the existing servo
amplifier ①. Check the names of the currently used cables. Check the abbreviations and short
names of the connectors to the replacing servo amplifier. Connect the cables and the connectors.
(See Fig. 1 to make sure which terminals you must connect.)
Fig. 1
Destination of Connection
L
L
11
11
L
L
21
21
J2S
J4
terminal
terminal
block
block
①Currently Used Cables L11 and L21
For the details of how to connect
the cables, see Fig. 1 and the
technical materials on the MR-J4
servo amplifier issued by
Mitsubishi Electric.
* Use caution not to incorrectly connect the currently used cables.
If you make an incorrect connection, the amplifier may be broken.
3-36
3 - 36
* If the currently used cables on
terminals L11 and L21 are too short,
see section 3.3.6, paragraph (5).