3. CC-Link COMMUNICATION FUNCTIONS
Signal name
Instruction code execution
completion
Warning
Battery warning
Movement finish
Position range
Position instruction
execution completion
Speed instruction
execution completion
Refer to Instruction code execution demand.
RXnA turns ON when a warning occurs.
When no warning has occurred, RXnA turns OFF within 1s after
power-on.
RXnB turns ON when Open battery cable warning (AL.92) or
Battery warning (AL.9F) occurs. When no battery warning has
occurred, RXnB turns OFF within 1s after power-on.
RXnC turns ON when In position (RXn1) turns ON and the
command remaining distance is "0".
RXnC turns ON at servo-on.
RXnE turns ON when the actual current position falls within the
range set in the parameter.
It is OFF when a home position return is not yet completed or
while the base circuit is off.
Refer to Speed instruction execution demand (RY(n+2)0).
Refer to Position instruction execution demand (RY(n+2)1).
Description
3 - 19
Device No.
1 station
2 stations
occupied
occupied
RXn9
RXn9
RXnA
RXnA
RXnB
RXnB
RXnC
RXnC
RXnE
RXnE
RX(n+2)0
RX(n+2)1