14. CHARACTERISTICS

14.5 Inrush currents at power-on of main circuit and control circuit

The following table indicates the inrush currents (measurement data) that will flow when the maximum
permissible voltage (253VAC) is applied at the power supply capacity of 2500kVA and the wiring length of
10m.
Servo Amplifier
MR-J2S-10CP-S084
20CP-S084
MR-J2S-40CP-S084
60CP-S084
MR-J2S-70CP-S084
100CP-S084
MR-J2S-200CP-S084
350CP-S084
MR-J2S-500CP-S084
MR-J2S-700CP-S084
MR-J2S-10CP1-S084
20CP1-S084
MR-J2S-40CP1-S084
Since large inrush currents flow in the power supplies, always use no-fuse breakers and magnetic
contactors. (Refer to Section 15.2.2.)
When circuit protectors are used, it is recommended to use the inertia delay type that will not be tripped
by an inrush current.
Main circuit power supply (L
30A (Attenuated to approx. 5A in 10ms)
30A (Attenuated to approx. 5A in 10ms)
54A (Attenuated to approx. 12A in 10ms)
120A (Attenuated to approx. 12A in 20ms)
44A (Attenuated to approx. 20A in 20ms)
88A (Attenuated to approx. 20A in 20ms)
59A (Attenuated to approx. 5A in 4ms)
72A (Attenuated to approx. 5A in 4ms)
Inrush Currents (Aop)
-L
)
Control circuit power supply (L
1
3
(Attenuated to approx. 0A in 0.5 to 1ms)
(Attenuated to approx. 0A in 0.5 to 1ms)
(Attenuated to approx. 0A in several ms)
(Attenuated to approx. 0A in 0.5 to 1ms)
14 - 7
-L
)
11
21
70 to 100A
100 to 130A
30A
100 to 130A