15. OPTIONS AND AUXILIARY EQUIPMENT
15. OPTIONS AND AUXILIARY EQUIPMENT
WARNING
CAUTION
15.1 Options
15.1.1 Regenerative brake options
CAUTION
(1) Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Servo amplifier
Built-in regenerative
brake resistor
MR-J2S-10CP(1)
-S084
MR-J2S-20CP (1)
-S084
MR-J2S-40CP (1)
-S084
MR-J2S-60CP-
S084
MR-J2S-70CP-
S084
MR-J2S-100CP-
S084
MR-J2S-200CP-
S084
MR-J2S-350CP-
S084
MR-J2S-500CP-
S084
MR-J2S-700CP-
S084
Note: Always install a cooling fan.
Before connecting any option or auxiliary equipment, make sure that the charge
lamp is off more than 10 minutes after power-off, then confirm the voltage with a
tester or the like. Otherwise, you may get an electric shock.
Use the specified auxiliary equipment and options. Unspecified ones may lead to a
fault or fire.
The specified combinations of regenerative brake options and servo amplifiers
may only be used. Otherwise, a fire may occur.
MR-RB032
[40 ]
30
10
30
10
30
10
30
20
30
20
30
100
100
130
170
Regenerative power[W]
MR-RB12
MR-RB32
MR-RB30
[40 ]
[40 ]
100
100
100
100
300
100
300
15 - 1
(Note)
MR-RB31
MR-RB50
[13 ]
[6.7 ]
[13 ]
300
500
300
500
300
500
(Note)
MR-RB51
[6.7 ]
300
500