6. PARAMETERS
Class No. Symbol
79
*DI1
Input device selection
Used to select the functions of the CN1A-8 and CN1A-19 pins.
Set value
80
*DI2
Input device selection 2
Used to select the functions of the CN1B-5 and CN1B-7 pins.
Name and Function
Set the function of the CN1A-8 pin.
The set value and its function are the same as
those of the CN1A-19 pin.
Set the function of the CN1A-19 pin.
Input selection
00
Without assigned function
01
Forced stop
02
Servo-on
03
Reset
04
Forward rotation stroke end
05
Reverse rotation stroke end
06
Forward rotation start
07
Reverse rotation start
08
Automatic/manual selection
09
Proximity dog
0A
0B
0C
0D
0E
0F
10
Internal torque limit selection
11
Proportion control
12
Temporary stop/Restart
Set the function of the CN1B-5 pin.
The set value and its function are the same as those of the
CN1A-19 pin. Refer to parameter No. 79 (input device
selection 1).
Set the function of the CN1B-7 pin.
The set value and its function are the same as those of the
CN1A-19 pin. Refer to parameter No. 79 (input device
selection 1).
Set value
Input selection
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
Point table No. selection 1
21
Point table No. selection 2
22
Point table No. selection 3
23
Point table No. selection 4
24
Point table No. selection 5
25
6 - 17
Initial
Setting
Unit
value
range
0000
Refer to
Name
and
function
column.
0900
Refer to
Name
and
function
column.