1. FUNCTIONS AND CONFIGURATION
1.1.3 System configuration
This section provides operations using this servo.
Use of CC-Link enables you to freely configure any system from a single-axis system to an up to 42-axis
system. Further, you can assign external input signals to the pins of the connector CN1A and CN1B by
setting parameter No. 116 to 118 and parameter No. 79 to 83.
Set the following values to the point table:
Name
Position data
Servo motor speed
Acceleration time constant
Deceleration time constant
Dwell
Auxiliary function
Up to 31 points can be set to the point table.
Setting range
999999 to 999999
0 to max. speed
0 to 20000
0 to 20000
0 to 20000
0 1
(Refer to Section 4.2)
1 - 4
Unit
0.001[mm]
0.01[mm]
0.1[mm]
1[mm]
[r/min]
[ms]
[ms]
[ms]