6 RAPID reference

6.1 Data types

6.1.1 be_device - Device data

Usage
be_device contains parameters that are used to describe the scanning device's
properties.
Components
SignalName
Data type: string
Digital input name used by the scanning device.
SenseHigh
Data type: bool
Set to true if signal is high when the detecting the tool.
SlowScanSpeed
Data type: speeddata
Slow scans will be executed with this speed setting.
See Technical reference manual - RAPID Instructions, Functions and Data types
for an explanation of speeddata.
FastScanSpeed
Data type: speeddata
Fast scans will be executed with this speed setting.
See Technical reference manual - RAPID Instructions, Functions and Data types
for an explanation of speeddata.
Repeatability
Data type: num
The expected repeatability for TCP measurements. This number should be about
twice that of the published repeatability for the robot arm. This equates to about
+/- 0.12 mm for an IRB 1400. Other factors, such as torch leads exerting undue
force on the tool mount bracket, may have an adverse affect on the repeatability.
In such cases it may be necessary to increase Repeatability in order for the robot
to find an acceptable solution. A convergence error is reported via the BullsEye
error code argument when the system cannot reach the desired repeatability within
a reasonable time.
Units: mm
Application manual - BullsEye
3HAC050989-001 Revision: C
© Copyright 2004-2018 ABB. All rights reserved.
6 RAPID reference
6.1.1 be_device - Device data
Continues on next page
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

0503060880

Table of Contents