Connecting Stations And Additional Equipment; Connecting Stations - Samsung OfficeServ 7400 Technical Manual

Hide thumbs Also See for OfficeServ 7400:
Table of Contents

Advertisement

OfficeServ 7400
TECHNICAL MANUAL
PART 7. CONNECTING STATIONS AND ADDITIONAL
EQUIPMENT
This section describes how to connect various stations and additional equipment, such as
analog/digital phones, door phones and door locks, to the OfficeServ 7400 system.

7.1 CONNECTING STATIONS

7.1.1 Safety Precautions
To reduce the risk of personal injury, follow these precautions before connecting telephone
circuits:
 Never install telephone wiring during a lightning storm.
 Never install telephone jacks in a wet location unless the jack is specifically designed for
wet locations.
 Do not connect stations in a humid area.
 Never touch non-insulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
 Connect stations using #24 AWG or #26 AWG cables.
The maximum distance between stations and the OfficeServ 7400 are as follows:
Digital phone
Analog phone
Door phone
AOM (Add-On Module)
NOTE: If you are connecting Samsung DCS keysets, the keyset version must be 1.2 or
higher.
Table 7.1 Distance Between Stations and the System
Station
7.1
Home Page
Home Page
Distance
Maximum 400m/1312ft (for AWG #24)
Maximum 1km/3280ft (for AWG #24)
Maximum 400m/1312ft (for AWG #24)
Maximum 400m/1312ft (for AWG #24)