95
4. Create a unique Data block for the control of the drive by enabling Manual option and by
selecting the Number.
Figure 96 FB500 DB1
Drive status and more will be stored in this Data block. Since it is a new Data block, you have to
generate it by clicking OK in the Call options window.
Note: If you add more drives to the program, make sure to create new unique Data blocks.
5. Connect the block inputs and outputs to variables according to your application.
Figure 97 Assigned variables
Note: Select a block input or output and see more information in the Info.
For more information on block variables and data types, see section
types
(page 60).
Block variables and data