ABB ACSM1 Firmware Manual page 91

Motion control drives, speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

10.05 EXT2 START IN1
Selects the source 1 for the start and stop commands in external control location EXT2. See
parameter
10.04 EXT2 START FUNC
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.06 EXT2 START IN2
Selects the source 2 for the start and stop commands in external control location EXT2. See
parameter
10.04 EXT2 START FUNC
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.07 JOG1 START
If enabled by parameter
1. 1 = Active. (Jogging function 1 can also be activated through fieldbus regardless of parameter
10.15.)
See section
Jogging
10.15 JOG
ENABLE,
24.11 SPEED REF
SPEED
DELAY.
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.08 FAULT RESET SEL
Selects the source for the external fault reset signal. The signal resets the drive after a fault trip if the
cause of the fault no longer exists. 1 = Fault reset.
Bit pointer: Group, index and bit
10.09 RUN ENABLE
Selects the source for the run enable signal. If the run enable signal is switched off, the drive will not
start or stops if the drive is running. 1 = Run enable.
See also parameter
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
10.10 EM STOP OFF3
Selects the source for the emergency stop OFF3. 0 = OFF3 active: The drive is stopped along the
emergency stop ramp time,
Emergency stop can also be activated through fieldbus
See section
Emergency stop
Note: This parameter cannot be changed while the drive is running.
Bit pointer: Group, index and bit
FW block:
DRIVE LOGIC
selections
FW block:
DRIVE LOGIC
selection
FW block:
DRIVE LOGIC
10.15 JOG
ENABLE, selects the source for the activation of jogging function
on page 47. See also other jogging function parameters:
24.03 SPEED REF1 IN
JOG2,
25.09 ACC TIME
JOGGING,
FW block:
DRIVE LOGIC
FW block:
DRIVE LOGIC
10.17 START
ENABLE.
FW block:
DRIVE LOGIC
25.11 EM STOP
on page 55.
(see above)
(1) In1
and
(2)
3-wire.
(see above)
(2)
3-wire.
(see above)
/
24.04 SPEED REF2
IN,
25.10 DEC TIME JOGGING
(see above)
(see above)
(see above)
TIME.
(2.12 FBA MAIN
Parameters and firmware blocks
10.14 JOG2
START,
24.10 SPEED REF
JOG1,
and
22.06 ZERO
CW).
91

Advertisement

Table of Contents
loading

Table of Contents