Explosion Proof Rtd Probe Assembly; Figure 2-6 Rtd Probe Wiring; Figure 2-7 Explosion Proof Rtd Overview - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

6) Insert the wires through the cord connector, and continue through the
7) Screw the cord connector into the adaptor bushing, and tighten.
8) Inside of the G4 EX enclosure, begin by disconnecting the connector plug
9) Using the supplied wiring instructions, make the field connections to the
10) Following the connection of the RTD Thermowell, secure the cable to the

2.2.6 Explosion proof RTD probe assembly

If the G4 EX is installed in a DIV 1 area, the explosion proof RTD must be used
(see Figure 2–7). The following procedures assume that the explosion proof RTD
kit was purchased as an option. For additional information, refer to the Wiring
Interconnect and Application Instructions that were supplied with the kit.
2.2.6.1
-
-
-
-
-
Page 2–8
adaptor bushing into the enclosure (see Figure 2–6).
from the RTD connection, J8, to begin field wiring.
Figure 2–6 RTD probe wiring
connector plug, and re-insert into the J8 board connector.
meter run pipe with plastic tie wraps. Do not wrap cable around the meter
run pipe.
HEAD
CUSTOMER
SUPPLIED LINE
Figure 2–7 Explosion proof RTD overview
Materials supplied
RTD probe (see Table 1–7 in Chapter 1 for available parts)
Optional Thermowell (see Table 1–8 in Chapter 1 for available parts)
Explosion proof connection head
Conduit union
Nipple fitting
UNION
NIPPLE
THERMOWELL
METER RUN
2104349 rev. AD

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries g4 6201ex

Table of Contents