Figure 5-2 Lcd And Indicators; Table 5-1 Visual Alarm Codes - ABB XSeries G4 6200 User Manual

Flow computer
Table of Contents

Advertisement

An application can be assigned to an annunciator, and any alarms or status codes
associated with that application will be displayed.
Indicator
Description
Low Lithium Battery Alarm: When displayed, the lithium battery voltage is
L
below 2.5 VDC. If battery voltage is above 2.5 VDC, A1 appears shaded. A
L
new lithium battery measures approximately 3.6 VDC.
Low Charger: This is displayed if the G4 EX battery charging voltage is less
L
than (+)0.4 VDC higher than the battery voltage. If charging voltage is (+)0.4
C
VDC greater than the battery voltage, the annunciator is shaded.
A to D Failure: Displayed if the A to D Converter absolute differential pressure,
absolute static pressure or temperature readings exceed maximum counts or
A
D
are less than the minimum counts. If the A to D Converter readings are within
range, AD is shaded.
Transmitting Data: Sending a response.
Receiving Data: Processing request.
!
Nak: Negative Acknowledgement w/packet list.
+
Ack: Positive Acknowledgement of receipt request.
Waiting for ACK: Waiting for response after transmission.
?
Exception Alarm Proceeding.
ID Recognized: Recognized and receiving request.
Listen Cycle: Flashes if this remote port is active and running Totalflow
Remote Protocol. Flashes in sync with listening cycle that occurs at 1, 2 or 4
second intervals.
MODBUS ASCII: MODBUS ASCII protocol selected for the port assigned to
M
this annunciator.
MODBUS RTU: MODBUS RTU protocol is selected for the port assigned to
m
this annunciator.
¥
ID Recognized: The ID has been recognized but is waiting for Sync.
2104349 rev. AD
Figure 5–2 LCD and indicators
Table 5–1 Visual alarm codes
I/O Subsystem
Measurement Application
Communication Protocols
Alarm
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
Page 5–3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries g4 6201ex

Table of Contents