The page number can be selected between O and 252 and is simply used for documentation.
The page address set on the module can be entered here (=> Section 3,3.2 "Setting the Mod-
ule Address"), The number can then be read at the programmer without having to remove the
positioning module from the PC, No check is made as to whether the page address on the mod-
ule is the same,
4.3.23

Read SYSID (Mode 70)

Using mode 70 (read SYSID), you can read the module identifier of the IP247 using FBI 65. This
is possible via all pages. The parameters are explained in the previous section,
For more detailed information about calling mode 70 refer to the description of FBI 65 in Section
6.3.8.3 "Structure of the IP247 SYSID in the PC Memory".
The data read are then displayed in the appropriate fields (=> Section 5.4 "Start COM247"),

Description of the Individual Monitoring Modes

4 . 4
Using the monitoring modes, you can call current information from the module. The monitoring
modes are as follows:
Mode number
66
71
73
74
The monitoring modes do not appear directly on the PG interface. They are used internally by
the COM247 software package.
Monitoring modes do not influence the operating mode and can be executed at any time regard-
less of the axis status.
On the PC interface, the monitoring modes 71 and 73 are started with FB1 64, the monitoring
mode 66 is started with FBI 65.
Description of the Individual Monitoring Modes
Type
Read actual values
Actual position value
Distance to go
Monitoring off
Execute with
FBI 64
FBI 64
4 - 4 3