6 Standard Function Blocks FB164 and FB165

General Notes

Overview

6.1.1
This part describes the two standard function blocks
"operating and monitoring the positioning module" and
FBI 64 (PER:POS)
"positioning module parameter assignment"
FBI 65(PER:PDAT')
FBI 64 is used to operate and monitor the IP247 positioning module. With FBI 64 you can start
the IP247 operating modes BA1 - BA17from the user program. FB164 also supplies constantly
updated information about the current status of an axis (errors, M-functions, ...). A
of the monitoring modes is started, the selected value is read and output cyclically by FBI 64.
FBI 65 is used to assign parameters to the IP247. It is responsible for the data exchange between
your user program and the IP247. By calling FB165, you can execute the following functions via
the PC interface:
read machine data and machining programs from the I P247, delete them and transfer
them to the IP247
read the system identification from the IP247 and transfer it to the IP247,
request an overview of the machine data or machining programs stored on the IP247 and
read actual values (actual position value, distance to go).
The function blocks FBI 64 andFB165 are used in the following programmable controllers
(CPU 941 tocPu 944)
S5-115U
(CPU 922 and CPU 928)
in conjunction with the following IP247 positioning modules
6ES5247-4UA31
This User's Guide assumes that you are familiar with the IP247 and the programmable controller.
Siemens AG°C79000-B8576 -C707-01
(for ventilated operation)
(for non-ventilated operation)
General Notes
soon as one
S
6-1