Notes; Overview Of The Data Handling Blocks; Installing An Interface In Ob20, Ob21 Or Ob22 With The S5-135U - Siemens SIMATIC S5 Manual

Positioning module 1p 247 for stepper motors
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Genera/Notes
The function blocks FBI 64 and FBI 65 are supplied on the diskette with one example under one
of the following file names:
S5-115U all CPUs
S5-155U
6.1.2

Notes

The IP247 positioning module is addressed by means of pages. It has three positioning axes and
a data channel and therefore requires four page addresses.
Function block FBI 64 must be called once for each axis.
Function block FB165 can be called conditionally.
Calls in the processor time interrupt OBS are not permitted.
The function blocks FBI 64 and FBI 65 operate with the data handling blocks SEND and RE-
CEIVE, FB165 also requires the FETCH data handling block.
The handling blocks are (automatically) assigned parameters and called by the FBs. The pages
must beset up in the start-up OB (OB20, OB21 and OB22 or OB21 and OB22 for the S5-1 15U)
with the SYNCHRON data handling block (FB1 25, FB185 and FB249).
6.1.2.1

Overview of the Data Handling Blocks

RECEIVE
FETCH

Installing an Interface in OB20, OB21 or OB22 with the S5-135U

6.1.2.2
: JU FB125
NAME
SSNR
BLGR
PAFE
6 - 2
:
:
:
:
S5-11 5U
S5-135U
FB244
I
FB245
FB246
Interface 2
Block size
SYNCH RON call - parameter assignment error
FY1
S5-150U
S5-155U
FB180
I
I
Siemens AG@C79000-B6576 -C707-01
1
J
Only for FB165