Table B–9: MODBUS MEMORY MAP (Sheet 56 of 57)
ADDR
REGISTER NAME
EB58
PMU 1 Voltage Trigger Dropout Time
EB59
PMU 1 Voltage Trigger Block (3 items)
EB5C
PMU 1 Voltage Trigger Target
EB5D
PMU 1 Voltage Trigger Events
EB5E
...Repeated for PMU 2
EB68
...Repeated for PMU 3
EB72
...Repeated for PMU 4
Phasor Measurement Unit One-shot Command (Read/Write Setting)
EB82
PMU One-shot Function
EB83
PMU One-shot Sequence Number
EB84
PMU One-shot Time
Phasor Measurement Unit Test Values (Read/Write Setting)
EB86
PMU 1 Test Function
EB87
PMU 1 Phase A Voltage Test Magnitude
EB89
PMU 1 Phase A Voltage Test Angle
EB8A
PMU 1 Phase B Voltage Test Magnitude
EB8C
PMU 1 Phase B Voltage Test Angle
EB8D
PMU 1 Phase C Voltage Test Magnitude
EB8F
PMU 1 Phase C Voltage Test Angle
EB90
PMU 1 Auxiliary Voltage Test Magnitude
EB92
PMU 1 Auxiliary Voltage Test Angle
EB93
PMU 1 Phase A Current Test Magnitude
EB95
PMU 1 Phase A Current Test Angle
EB96
PMU 1 Phase B Current Test Magnitude
EB98
PMU 1 Phase B Current Test Angle
EB99
PMU 1 Phase C Current Test Magnitude
EB9B
PMU 1 Phase C Current Test Angle
EB9C
PMU 1 Ground Current Test Magnitude
EB9E
PMU 1 Ground Current Test Angle
EB9F
PMU 1 Test Frequency
EBA1
PMU 1 Test df/dt
EBA2
...Repeated for PMU 2
EBBE
...Repeated for PMU 3
EBDA
...Repeated for PMU 4
Phasor Measurement Unit Recorder Configuration Counter Command (Read/Write Command)
EBF6
PMU 1 Recorder Clear Configuration Counter
EBF7
...Repeated for PMU 2
EBF8
...Repeated for PMU 3
EBF9
...Repeated for PMU 4
Phasor Measurement Unit Recording Values (Read Only)
EBFA
PMU 1 Available Records
EBFB
PMU 1 Second Per Record
EBFD
PMU 1 Last Cleared Date
EBFE
...Repeated for module number 2
EC02
...Repeated for module number 3
EC06
...Repeated for module number 4
Direct integers (read/write setting registers)
EC40
Direct integer output 1 value
EC41
Direct integer output 1 trigger
EC42
Direct integer input 1 device
EC43
Direct integer input 1 number
EC44
Direct integer input 1 default value
EC46
Direct integer input 1 mode
EC47
Reserved
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
0 to 600
s
0 to 65535
---
0 to 2
---
0 to 1
---
0 to 1
---
0 to 59
---
0 to 235959
---
0 to 1
---
0 to 700
kV
-180 to 180
°
0 to 700
kV
-180 to 180
°
0 to 700
kV
-180 to 180
°
0 to 700
kV
-180 to 180
°
0 to 9.999
kA
0.001
-180 to 180
°
0 to 9.999
kA
0.001
-180 to 180
°
0 to 9.999
kA
0.001
-180 to 180
°
0 to 9.999
kA
0.001
-180 to 180
°
20 to 70
Hz
0.001
-10 to 10
Hz/s
0.001
0 to 1
---
0 to 65535
---
0 to 6553.5
---
0 to 400000000
---
0 to 65535
---
0 to 65535
---
0 to 16
---
0 to 16
---
0 to 4294967295
---
0 to 1
---
---
---
B.4 MEMORY MAPPING
FORMAT
DEFAULT
0.01
F001
100
1
F300
0
1
F109
0 (Self-reset)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F001
1
1
F050
0
1
F102
0 (Disabled)
0.01
F003
50000
0.05
F002
0
0.01
F003
50000
0.05
F002
-120
0.01
F003
50000
0.05
F002
120
0.01
F003
50000
0.05
F002
0
F004
1000
0.05
F002
-10
F004
1000
0.05
F002
-130
F003
1000
0.05
F002
110
F004
0
0.05
F002
0
F003
60000
F002
0
1
F126
0 (No)
1
F001
0
0.1
F001
0
1
F050
0
1
F612
0
1
F300
0
1
F001
0
1
F001
0
1
F003
1000
1
F491
0 (Default Value)
---
---
---
B
B-63