GE N60 Instruction Manual page 416

Network stability and synchrophasor measurement system ur series
Hide thumbs Also See for N60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 13 of 57)
ADDR
REGISTER NAME
40C9
DNP TCP connection timeout
40CA
Reserved (22 items)
40E0
TCP port number for the IEC 60870-5-104 protocol
40E1
IEC 60870-5-104 protocol function
40E2
IEC 60870-5-104 protocol common address of ASDU
B
40E3
IEC 60870-5-104 protocol cyclic data transmit period
40E4
IEC 60870-5-104 current default threshold
40E6
IEC 60870-5-104 voltage default threshold
40E8
IEC 60870-5-104 power default threshold
40EA
IEC 60870-5-104 energy default threshold
40EC
IEC 60870-5-104 power default threshold
40EE
IEC 60870-5-104 other default threshold
40F0
IEC 60870-5-104 client address (5 items)
4104
IEC 60870-5-104 redundancy port
4005
Reserved (59 items)
4140
DNP object 1 default variation
4141
DNP object 2 default variation
4142
DNP object 20 default variation
4143
DNP object 21 default variation
4144
DNP object 22 default variation
4145
DNP object 23 default variation
4146
DNP object 30 default variation
4147
DNP object 32 default variation
Ethernet switch (Read/Write Setting)
4148
Ethernet switch IP address
414A
Ethernet switch Modbus IP port number
414B
Ethernet switch Port 1 Events
414C
Ethernet switch Port 2 Events
414D
Ethernet switch Port 3 Events
414E
Ethernet switch Port 4 Events
414F
Ethernet switch Port 5 Events
4150
Ethernet switch Port 6 Events
Ethernet switch (Read Only Actual Values)
4151
Ethernet switch MAC address
4154
Ethernet switch Port 1 Status
4155
Ethernet switch Port 2 Status
4156
Ethernet switch Port 3 Status
4157
Ethernet switch Port 4 Status
4158
Ethernet switch Port 5 Status
4159
Ethernet switch Port 6 Status
415A
Switch Firmware Version
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) function
4169
Simple Network Time Protocol (SNTP) server IP address
416B
Simple Network Time Protocol (SNTP) UDP port number
Data Logger Commands (Read/Write Command)
4170
Data Logger Clear
Data Logger (Read/Write Setting)
4181
Data Logger Channel Settings (16 items)
4191
Data Logger Mode
4192
Data Logger Trigger
4193
Data Logger Rate
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
B-20
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
STEP
10 to 65535
---
0 to 1
---
1 to 65535
---
0 to 1
---
0 to 65535
---
1 to 65535
s
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 4294967295
---
0 to 1
---
0 to 1
---
1 to 2
---
1 to 3
---
0 to 3
---
0 to 3
---
0 to 3
---
0 to 3
---
1 to 5
---
0 to 5
---
0 to 4294967295
---
1 to 65535
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
0 to 1
---
---
---
0 to 2
---
0 to 2
---
0 to 2
---
0 to 2
---
0 to 2
---
0 to 2
---
0.00 to 99.99
---
0 to 1
---
0 to 4294967295
---
1 to 65535
---
0 to 1
---
---
---
0 to 1
---
0 to 65535
---
15 to 3600000
ms
0 to 235959
---
APPENDIX B
FORMAT
DEFAULT
1
F001
120
1
F001
0
1
F001
2404
1
F102
0 (Disabled)
1
F001
0
1
F001
60
1
F001
30000
1
F001
30000
1
F001
30000
1
F001
30000
1
F001
30000
1
F001
30000
1
F003
0
1
F126
0 (No)
1
F001
0
1
F001
2
1
F001
2
1
F523
0 (1)
1
F524
0 (1)
1
F523
0 (1)
1
F523
0 (1)
1
F001
1
1
F525
0 (1)
1
F003
3232235778
1
F001
502
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F072
0
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F134
0 (Fail)
0.01
F001
0
1
F102
0 (Disabled)
1
F003
0
1
F001
123
1
F126
0 (No)
---
F600
0
1
F260
0 (continuous)
1
F300
0
1
F003
60000
1
F050
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents