Installation Guide
Step 3 Power on the RHUB. Wait 3 to 5 minutes, check the status of the RUN indicator of the RHUB
after the RHUB runs properly.
If the Status of
the RUN
Indicator...
Steady on
Steady off
On for 1s and off
for 1s
On for 0.125s and
off for 0.125s
----End
Issue 02 (2014-05-27)
It Indicates that...
The power supply is
normal while the board is
faulty.
There is no power input
or the board is faulty.
The devices work
properly.
The board software is
being uploaded.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Then...
Power off the RHUB, and power on it again
after rectifying the board fault.
Power off the RHUB, and check the power
input again. Rectify the board faulty and
power on the RHUB again if the power input
is normal.
End the operation.
Power off the RHUB if the uploading is not
finished in 5 minutes, and check whether the
configuration file is correct. Power on the
RHUB again after the fault is rectified.