4.
Remove the rubber grommets and cut adequate holes into
them. Slide the grommets onto the power cables the conical
part downwards. Seal the lead-through plate holes with the
grommets.
5.
Strip off the outer sheathing of the cables under the 360
degrees grounding clamps and fasten the clamps onto the
stripped parts of the cables.
6.
Twist the shields of the cables into pigtails and connect the
pig tails under the grounding screws with cable lugs. Keep
the pigtails short to minimize electromagnetic emission. See
the following two figures.
7.
Connect the motor cable conductors to the U2, V2 and W2
terminals.