4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE
4.1.8.3 METERING
The Metering menu includes all the measurements available in the device. Primary and secondary values, and also the
data related to the recording functions in the relay.
Table 4–21: GENERAL OVERVIEW OF METERING MENU:
METERING
4.1.8.4 INPUTS/OUTPUTS
The Inputs/Outputs menu includes all the inputs and outputs signals available in the device. Contact and virtual type.
Table 4–22: GENERAL OVERVIEW OF INPUTS/OUTPUTS MENU:
INPUTS/
4
OUTPUTS
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)

4.1.8.5 RECORDS

The Records menu is only available in on line mode and includes the possibility to retrieve all the records available in the
device. By serial or Ethernet.
Table 4–23: GENERAL OVERVIEW OF RECORDS MENU:
RECORDS (*)
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
4-30
Primary Values
Primary values measurements for currents, voltages, power, energy and
demand
Secondary Values
Secondary values measurements for currents, voltages and power.
Phasor Diagram
Current, voltage and sequence components.
Frequency
Line and Bus frequencies.
Contact Inputs
Status of digital inputs in the Relay for each board according to the relay
model.
Contact Output Status
Status of digital outputs in the Relay for each board according to the relay
model.
Contact Outputs
Status (activated or not) of the variables used to operate a contact
Operates
output. To configure these signals go to "Settings>Relay
Configuration>Outputs" menu.
Contact Outputs
Status (activated or not) of the variables used to reset a contact output.
Resets
To configure these signals go to "Settings>Relay Configuration>Outputs"
menu. This output reset Command will only be effective if the "latch"
option has been Selected for the "Output Type" setting on the I/O board,
thus when the contact output has been configured to emulate function 86
(latching relay).
IO Board Status
Status of I/O boards. This status provides if the hardware it is OK (boards
matching relay model, correctly inserted in their tracks, in good state and
communicating through the internal CAN Bus).
Virtual Inputs
Status of Virtual inputs latched (32) and self-reset (32).
Virtual Outputs
Status of virtual outputs (configured in PLC Editor). Up to 512.
Remote Outputs
States of remote outputs

Remote Inputs

Status of remote device and remote inputs
Analog Inputs (*)
Measurements coming from analog inputs (DCMA)
Event recorder (*)
Retrieval and visualization of snapshot event (all and new), control
events and alarm panel. By serial or Ethernet (ModBus RTU or TCP/IP)
Waveform capture (*)
Retrieval of oscillography files, by serial or Ethernet.
Fault Report (*)
Retrieval and visualization of fault report files, by serial or Ethernet.
Data logger (*)
Retrieval and visualization of data logger files. Only by Ethernet.
F650 Digital Bay Controller