ABB AC 31 Technical Manual page 54

Advant controller 31 40 & 50 series
Hide thumbs Also See for AC 31:
Table of Contents

Advertisement

Incorporated outputs
- Number of outputs
- Isolation of the inputs / electronic
- Total charging current
under voltage:
direct 24 V d.c.
resistive load / inrush current
L / R = 20 ms
L / R = 30 ms
L / R = 40 ms
L / R = 60 ms
alternate 24 to 230 V a.c.
- Total charging current
- Output leakage current
- Output waste voltage
- Minimum cut-off values
- Breaking capacity under 120 V a.c.
(contact rating code B300) (UL)
- Breaking capacity under 250 V a.c.
(contact rating code B300) (UL)
- Number of common
- Switching frequency:
for resistive loads
for inductive loads
for lamps
- Number of switches:
for AC-1
for AC-15
- Short circuit and overload
protection
- Surge voltage protection
- Outputs diagnosis
- Cable length:
unshielded
shielded
ABB Control - AC 31
1SBC 260400 R1001-b
06.99
Technical specifications
40 series
07 CR 41
07 CT 41
24 V d.c.
24 V d.c.
6 relays
6 transistors
1500 Vrms
1500 V a.c.
1 min
2 A / 5 A
1 A for
2 A
O62.00 and
1 A
O62.01 and
0.6 A
0.5 A for
0.35 A
other outputs
2 A AC-1
0.5 A AC-15
6 x 2 A
4 x 0.5 A
+ 2 x 1 A
-
< 200 µA
-
0.5 V to
500 mA max.
10 mA under
12 V
12 V d.c.
2 A
2 A (1.5 A
according
to UL)
2 (2+4)
< 1 Hz
5 kHz
< 0.2 Hz
< 0.2 Hz
1 million
100 000
envisage
externally
thermic
envisage
externally
no
overload and
short circuit
150 m
150 m
500 m
500 m
07 CR 41
120/230 V a.c.
6 relays
1500 Vrms
1 min
2 A / 5 A
2 A
1 A
0.6 A
0.35 A
-
2 A AC-1
0.5 A AC-15
6 x 2 A
-
-
10 mA under
10 mA under
12 V d.c.
2 A
2 A (1.5 A
according
to UL)
2 (2+4)
< 1 Hz
< 0.2 Hz
< 0.2 Hz
-
1 million
-
100 000
yes:
envisage
externally
yes
envisage
externally
no
150 m
500 m
50 series
07 KR 51
07 KT 51
24 V d.c.
24 V d.c.
6 relays
6 transistors
1500 Vrms
1500 V a.c.
1 min
2 A / 5 A
1 A for
2 A
O62.00 and
1 A
O62.01 and
0.6 A
0.5 A for
0.35 A
other outputs
2 A AC-1
-
0.5 A AC-15
6 x 2 A
4 x 0.5 A
+ 2 x 1 A
-
< 200 µA
-
0.5 V to
500 mA max.
12V
12 V d.c.
2 A
2 A (1.5 A
according
to UL)
2 (2+4)
< 1 Hz
5 kHz
< 0.2 Hz
< 0.2 Hz
1 million
-
100 000
-
envisage
yes:
externally
thermic
envisage
yes
externally
no
overload and
short circuit
150 m
150 m
500 m
500 m
07 KR 51
120/230 V a.c.
6 relays
1500 Vrms
1 min
2 A / 5 A
2 A
1 A
0.6 A
0.35 A
2 A AC-1
0.5 A AC-15
6 x 2 A
-
-
10 mA under
12 V d.c.
2 A
2 A (1.5 A
according
to UL)
2 (2+4)
< 1 Hz
< 0.2 Hz
< 0.2 Hz
1 million
100 000
envisage
externally
envisage
externally
no
150 m
500 m
Page 3-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents