Programming

5.7.3. TP: monostable (constant)

This block enables the activation of an output during a fixed time as from the moment when a
rising edge appears on the input. A new rising edge will not be taken into account if it appears
on the input before the timer time has been completed.
%I62.00
%KD001.00
IN
Q
PT

5.7.4. TIME_W:

The function TIME_W can be used to display elapse time on the display extension XTC 08
%MD000.00

5.7.5. W_TIME:

The function W_TIME is needed when the time value has to be modified during program (i.e.
Control panel, supervisor, set point validation...)
%OW63.00
%OW63.01
%OW63.02
%OW63.03
%I62.00
%MD000.00
TP
%O62.00
IN
Q
%MD000.00
PT
ET
PT
TIME_W
%OW63.00
H
%OW63.01
MN
%OW63.02
SEC
%OW63.03
TIME
MS
W_TIME
H
MN
SEC
%MD000.00
MS
TIME
TON
%O62.00
IN
Q
%MD000.01
PT
ET
Page 5-39