204
Fault
Code
31
32
33
34
35
36
101
102
103
104
105
201
202
203
204
205
206
207
Diagnostics
Fault Name In
Panel
1
Fault code reserved for the embedded fieldbus (EFB) protocol application.
EFB
The meaning is protocol dependent.
2
EFB
3
EFB
Fault in the motor circuit. One of the motor phases is lost. Check for and
MOTOR PHASE
correct:
• Motor fault.
• Motor cable fault.
• Thermal relay fault (if used).
• Internal fault.
Possible power wiring error detected. When the drive is not running it
OUTPUT WIRING
monitors for an improper connection between the drive input power and the
drive output. Check for and correct:
• Proper input wiring – line voltage is NOT connected to drive output.
• The fault can be erroneously declared if the input power is a delta
grounded system and motor cable capacitance is large. This fault can be
disabled using parameter 3023
The drive cannot use the software.
INCOMP
SWTYPE
• Internal Fault.
• The loaded software is not compatible with the drive.
• Call support representative.
Error internal to the drive. Contact your local ABB sales representative and
SERF CORRUPT
report the error number.
RESERVED
SERF MACRO
RESERVED
RESERVED
1
Error in the system. Contact your local ABB sales representative and report
DSP T
the error number.
OVERLOAD
2
DSP T
OVERLOAD
3
DSP T
OVERLOAD
DSP STACK
ERROR
RESERVED
(
)
OBSOLETE
OMIO ID ERROR
EFB LOAD
ERROR
Description and Recommended Corrective Action
WIRING FAULT
ACS550 User's Manual
.