Siemens Sinumerik 840D sl Diagnostic Manual page 76

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
Definitions:
This alarm is purely a development alarm. It only occurs with externally linked compile cycles.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is cancelled.
Remedy:
Consultation with CC developer
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7202
Missing option bit for %1: %2 <hex>
Parameters:
%1 = (string) name of the specific .elf file
%2 = (int) required option bit (hex)
Definitions:
Alarm for SIEMENS compile cycles. This alarm appears when the option bit required for a SIEMENS
compile cycle is not set.
Reaction:
NC not ready.
Channel not ready.
Interface signals are set.
Alarm display.
Alarm reaction delay is cancelled.
Remedy:
Set the required option bit or delete the .elf file from the Flash File System.
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7205
[Channel %1: ] Incompatible OEM transformation version NCK %2 CC
%3
Parameters:
%1 = (int) channel number
%2 = Transformer interface version NCK
%3 = Transformer interface version OEM
Definitions:
The interface for OEM transformations has changed incompatibly in the system.
Reaction:
NC not ready.
Channel not ready.
Interface signals are set.
Alarm display.
Alarm reaction delay is cancelled.
Remedy:
Load the new compile cycle version
Program Con-
Clear alarm with the RESET key in all channels. Restart part program.
tinuation:
7300
Problem with externally linked COA application %1 Index: %2 Additional
information: %3
Parameters:
%1 = Name of the COA application
%2 = Index describing the problem that occured in more detail
%3 = Optional additional parameter
Definitions:
A problem occurred while loading the COA application. This problem is described in more detail by
the parameters "Index" and "Additional information":
Index == 1: The interface version of the COA application is incompatible with the NCK version. The
additional information contains the interface version of the COA application.
Index == 2: The heap memory requested by the COA application is not available. The additional infor-
mation contains the heap memory requested in KB.
Index == 3: The $P_INCOAP parameters requested by the COA application cannot be created due to
insufficient memory. The additional information contains the heap memory requested in KB.
Reaction:
Alarm display.
2-76
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009