Siemens Sinumerik 840D sl Diagnostic Manual page 187

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14129
[Channel %1: ] Block %2 orientation angles and orientation vector
components programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An orientation angle and components of an orientation vector were programmed at the same time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14130
[Channel %1: ] Block %2 too many initialization values given
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
On assigning an array by means of SET, more initialization values than existing array elements have
been specified in the program run.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of initialization values.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
14131
[Channel %1: ] Block %2 orientation axes and lead/tilt angles
programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An orientation angle and a leading or sideways angle were programmed at the same time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14132
[Channel %1: ] Block %2 orientation axes incorrectly configured
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Possible causes:
- The configuration of the orientation axes does not match the machine kinematics. Also, for example,
when the position measuring system has not been set for the rotary axes.
- An axis that is required as orientation axis is currently not available as path axis.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adapt machine data.
Provide the required orientation axes using GET(..) or GETD(..).
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-187

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents